Deck underside first
We walk the bays with a light and a scraper. Flaking, pinholes and sagging flutes near the dryers tell us where the cores have to go.
How core sampling worksCar wash roofs in St. Louis fail from the inside out more often than from weather. Warm, chemical-laden vapor from tunnels and in-bay automatics condenses on the underside of the steel deck, rusts it, and soaks the insulation long before the membrane wears out. John Beal Roofing checks the deck from below, scopes membrane, curbs and edge metal for a wash environment, and schedules the work so bays keep running. Free inspections. Call (314) 429-6000.
We look at tunnel washes along Manchester Road and Gravois, in-bay automatics at gas stations out in St. Charles County, and the four- and six-bay self-serve buildings scattered through North County and the Metro East. Different buildings. Same enemy. Hot water, presoak chemicals and road salt end up in the air, and that air goes up.
Most car wash roofs we’re called to are steel deck on bar joists with a single-ply or mod bit on top, sometimes with standing seam over the vacuum canopy. From above, the membrane usually looks fine. Pull a core near the exit end of a tunnel, though, and you’ll often find wet polyiso sitting on a deck that’s flaking orange. That’s why we start under the roof, not on it.
We walk the bays with a light and a scraper. Flaking, pinholes and sagging flutes near the dryers tell us where the cores have to go.
How core sampling worksA vapor retarder on the warm side of the insulation keeps tunnel humidity out of the roof assembly. Plenty of older washes were built without one.
Vapor barriers on commercial roofsPVC holds up well where exhaust carries chemical residue onto the roof. A good TPO works on many self-serve buildings. We choose after seeing the fans.
TPO vs. EPDM vs. PVCTunnel exhaust fans dump wet, soapy air right onto the membrane. Curb height, counterflashing and a walk pad around each fan all matter.
Curb leak repairSteam rolling out of the bay doors freezes on fascia and gutters every January. We spec coated edge metal and check every fastener for rust.
Tear-off runs one section at a time, mostly off-peak. We coordinate with your site manager so the tunnel isn’t shut on a sunny Saturday.

Picture a January morning in Florissant. It’s eighteen degrees out and the tunnel’s pushing hot water through the arches. All that vapor climbs, hits a cold steel deck and turns back into water. Do that every open day for ten winters and the deck pays for it.
Chemicals make it worse. Presoaks, tire cleaners and wax ride the mist. Some of it lands on the roof through the exhaust fans, and some settles on the deck underside, where it speeds up rust that’s already started.
Then there’s salt. Cars roll in caked with brine off I-70 and I-270, and the spray carries it onto the walls, the door tracks and the bottom of the deck nearest the entrance. When we core a wash roof, the entrance and exit ends get cored first.
If the deck’s sound and the old roof is dry, a recover with new insulation and a vapor retarder can work. If cores show wet board or the deck’s thinned out, we’ll say so and price tear-off with deck replacement by the square foot. Our tear-off vs. recover guide walks through how that call gets made. You’ll see photos either way.
Usually, yes. We stage away from the entrance, keep material off the stacking lane, and run tear-off in sections we can dry in the same day. Deck replacement directly over the tunnel sometimes needs the bay closed for a shift, and we’ll put that on your slowest day.
On tunnel washes where exhaust carries residue onto the roof, it often is. On a self-serve building with little exhaust, a good TPO is usually fine. We’ll tell you which way we lean and why once we’ve seen the fans and the deck.
Because the water’s coming from inside. Warm, wet air condenses on the cold underside of the deck. Without a vapor retarder and enough insulation above the deck, that happens every cold day the wash runs.
Yes. We handle metal and membrane canopy tops and flash the curbs and supports for anything mounted on the roof. Electrical work on signs and lights stays with your sign company.
Our lifetime workmanship warranty, plus the manufacturer’s product warranty on the materials. We’ll walk you through anything the manufacturer excludes, chemical exposure included, before you sign.
Tell us about the wash and a dispatcher will call to schedule.
Commercial leaks do not wait for business hours. A live dispatcher answers around the clock and we get crews moving the same night.